Dear Matt, I'm not sure if you received my answer to your question, because I saw that my email only went to the FSL mailing list and not directly to you. So, I will send it again to you and hope not to bother you! The resting state data were recorded with the following sequence parameters: 3T magnetic field TR: 2.595 voxel size: 3.59 x 3.59 x 3.59 volumes: 250 subjects: 32 Apart from the question whether I have to use ICA-AROMA additionally after I have regressed the movement parameters, the order of the denoising steps after the preprocessing is not quite clear to me: 1) regressing out of movement parameters 2) ICA-AROMA - if necessary 3) regressing out of average white-matter and cerebrospinal fluid signals 4) high-passfiltering Is that procedure right or am I doing something wrong? Sorry for all the " basic" questions - I'm not that familiar with analyzing resting state data. Many thanks! Christine ######################################################################## To unsubscribe from the FSL list, click the following link: https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=FSL&A=1