On 9 Apr 2019, at 16:14, Dan Evans <[log in to unmask]> wrote:
Hello,
I have also encountered this problem, but only in a couple of my subjects. The subjects that throw this error are in the middle of the range of lesion volumes for my sample and lesion filling works for the extremes in the sample. Below is the command I've run and the output I get.
Read in imageslesion_filling -i Trac006_MPRAGE.nii -l Trac006_LM_thresh_0.4.nii.gz -w Trac006_WM_LM_combined.nii.gz -o Trac006_MPRAGE_filled.nii.gz -v
Counted lesions in mask : total = 75
Calculated outer border mask
Calculated outer border components
Calculated inner border and region masks
Component 1 of 75
Component 2 of 75
Component 3 of 75
Cols = 1 and rows = 0
WRONG ASSUMPTION ABOUT MATRIX METHOD IN NEWIMAGE!!!!!!
Cols = 1 and rows = 0
Calculating cummulative distribution
Random sampling...
libc++abi.dylib: terminating with uncaught exception of type NEWMAT::IndexException
Abort trap: 6
Thanks for any help!
Best,
Dan Evans
########################################################################
To unsubscribe from the FSL list, click the following link: