Dear Christian, Could you help me concerning my last request below ? Best, Matthieu Le mer. 9 janv. 2019 à 14:46, Matthieu Vanhoutte < [log in to unmask]> a écrit : > Dear CAT12's experts, > > I think I found how to choose the surfaces used during projection of > volume to surface thanks to the parameters "StartPoint", "StepSize" and > "EndPoint". > > 1) For example, if I want to project native volume with data ranging from > 35 to 65% of the cortical thickness with a step *t* = 5%, should I > specify "StartPoint=0.35", "StepSize=0.05" and "EndPoint=0.65" combined > with "Relative position within a tissue class" parameter ? > > 2) Is it possible to choose the weights associated to each surface used in > the projection ? > > 3) The "Map Volume (Native space) to Individual" surface fonction > specifies that functional volume has to be coregistered in the same space > as the T1 image. Does it suppose that native volume has to be "coregistered > and resliced" or just "coregistered without reslicing" in the same space as > the T1 image? > > Best, > Matt > > Le mar. 8 janv. 2019 à 11:38, Matthieu Vanhoutte < > [log in to unmask]> a écrit : > >> Dear CAT12's experts, >> >> I noticed that in the last version of CAT12 it was possible to project >> data from native volume to surface according mean signal or gaussian >> weighted signal (recommanded for fMRI). >> >> Could you inform me how many weighted are used for mean or gaussian >> weighting ? >> >> Would it be possible to personalize the weights and the associated >> surfaces used ? >> >> Best, >> Matt >> >