Hi Takanori et al,

As of December 27, I'm now also encountering the "unable to load micrograph" warning (although it's really a fatal error).
These micrographs were corrected using MotionCor2 from within Relion 3 beta, and then a subset selection was run. During training for Bayesian polishing I get

in: /home/heumannj/Downloads/relion-3.0_beta/src/rwSPIDER.h, line 151
warning: unable to load micrograph #1

for each of the 50 micrographs selected for training.

I just fetched from bitucket and re-built today, so everything should be the latest version. 
These are standard mode 2 files, and 3dmod, chimera, relion_display, and relion_image_handler --stats all read them with no trouble, e.g.:

relion_image_handler --stats --i MotionCorr/job002/Movies/SFXN-1_1-31kx-e55-03_1587.mrc
MotionCorr/job002/Movies/SFXN-1_1-31kx-e55-03_1587.mrc : (x,y,z,n)= 3838 x 3710 x 1 x 1 ; avg= 17.3153 stddev= 0.214862 minval= 15.9615 maxval= 18.5656

Thanks for any suggestions

Regards,
-jh-

########################################################################