Hi Mia,

the exact same error is also appearing when I do 2D classification with newly extracted particles. The job stops during noise spectra estimation.
I used relion_image_handler --stats --i particles.star to check the particles, but I assume they are all okay since I did not get any error and the values are quite similar for each particle.
Also disc I/O should be fine in our case. 
I also tried reautopicking and reextraction of the particles and still get the error.

Have you already tried with the latest version and got to some success?
Or did you come to another good solution?

Many thanks,
Thomas





> On 15 Oct 2018, at 22:00, Sjors Scheres <[log in to unmask]> wrote:
> 
> Hi Xiaofeng,
> Some image is probably corrupt. Disk I/O may be unreliable on your system.
> Use relion_image_handler --stats --i particles.star to find out which one
> it is, and try re-extraction.
> HTH
> Sjors
> 
>> Hi, I have received same error mesage when using RELION 3.0_beta. Do
>> anyone
>> find a solution?
>> 
>> Thanks,
>> 
>> Xiaofeng
>> 
>> Mia Shin <[log in to unmask]> 于2018年10月11日周四
>> 下午2:09写道:
>> 
>>> Hi all,
>>> 
>>> I have run motioncorr2, gCTF, auto-picking, particle extraction,
>>> sorting,
>>> and subset selection based on Z-score (almost identically to the RELION
>>> 3.0
>>> tutorial) and am receiving the following error during the initialization
>>> step before running 2D Classification in the gui:
>>> 
>>> ERROR:
>>> Backprojector::set2DSlice%%ERROR: Dimension of the data array should be
>>> 2
>>> or 3
>>> 
>>> I was wondering if anyone in the community has seen this error before or
>>> knows where it might come from? Thanks so much in advance.
>>> 
>>> 
>>> Best,
>>> 
>>> 
>>> Mia Shin
>>> 
>>> Graduate Student
>>> 
>>> The Scripps Research Institute
>>> 
>>> 
>>> 
>>> ------------------------------
>>> 
>>> To unsubscribe from the CCPEM list, click the following link:
>>> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
>>> 
>> 
>> ########################################################################
>> 
>> To unsubscribe from the CCPEM list, click the following link:
>> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1
>> 
> 
> 
> -- 
> Sjors Scheres
> MRC Laboratory of Molecular Biology
> Francis Crick Avenue, Cambridge Biomedical Campus
> Cambridge CB2 0QH, U.K.
> tel: +44 (0)1223 267061
> http://www2.mrc-lmb.cam.ac.uk/groups/scheres
> 
> ########################################################################
> 
> To unsubscribe from the CCPEM list, click the following link:
> https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1

########################################################################

To unsubscribe from the CCPEM list, click the following link:
https://www.jiscmail.ac.uk/cgi-bin/webadmin?SUBED1=CCPEM&A=1