Hello,
  I can’t replicate this locally using data of a similar range. However this may simply be an issue with how the values are being displayed: If these images are float32 then the difference occurs beyond the precision of the raw data.

Kind Regards
Matthew
--------------------------------
Dr Matthew Webster
FMRIB Centre 
John Radcliffe Hospital
University of Oxford

On 29 Jun 2018, at 10:46, Maria Torres P <[log in to unmask]> wrote:

Hello,

I have use fsl split in a .nii image but the spited volumes do not have exactly the same values as the original image (e.g  451.6688537597656 ---> 451.66886711120605). Any idea why may this be?