Print

Print


Hello,

thanks for your reply. This is the script that I've run:

oxford_asl -i /home/max/Scrivania/sb1/FUNC/PASL.nii -o
/home/max/Scrivania/pippo/  -s
/home/max/Scrivania/sb1/STRUC/T1_brain.nii.gz  -c
/home/max/Scrivania/sb1/FUNC/M0.nii --tr=3 --tis=1.8

But I still get the same error:

OXFORD_ASL - running
Saving results in natve (ASL aquisition) space to
/home/max/Scrivania/pippo//native_space
Saving results in structural space to
/home/max/Scrivania/pippo//struct_space
Pre-processing
Creating mask
Performing registration
ASL_REG
Input file is: /tmp/fsl_3gh19b_ox_asl/meanasl
Running FLIRT
Tidying up
ASL_REG - Done.
Calculating M0a - calling ASL_CALIB
ASL_CALIB
Tissue reference is: csf
M0:1410.13000000000000000000
ASL_calib - DONE.
/usr/local/fsl/bin/oxford_asl: 1176: /usr/local/fsl/bin/oxford_asl:
alltis[0]=1.8: not found
Number of inversion times: 1
Number of timepoints in data: 88
Number of repeats in data: 88

Any tips?

Davide



Davide Momi
-----------
PhD Candidate
Unit of Behavioral Economics and Neuroeconomics
Department of Neuroscience, Imaging and Clinical Sciences
University "G. d'Annunzio" of Chieti
Via dei Vestini 31, 66013 Chieti, Italy
Mobile ++39 - 348-2650293

2018-01-12 16:49 GMT+01:00 Michael Chappell <[log in to unmask]>:

> From your scan parameters you only have one TI (at least as far as
> oxford_asl understands the term). You are clearly using pASL and your TI is
> 1.8 (your TI2) seconds and your bolus duration is 0.7 seconds (your TI1).
>
> Michael
>
>
> On 12 Jan 2018, at 13:28, Davide Momi <[log in to unmask]> wrote:
>
> Dear FSL experts,
>
> From previous exchanges it wasn't clear to me what is the solution to this
> problem. The Oxford_ASL script produces an error:
> SCRIPT LINE: oxford_asl -i data_pasl/diffdata --tis 0.7, 1.8 -o ex1_1
> --bolus 1.1 --bat 0.7 --t1 1.3 --t1b 1.66 --artoff --spatial
>
> /usr/local/fsl/bin/oxford_asl: 1176: /usr/local/fsl/bin/oxford_asl: alltis
> [0]= 0: not found
> /usr/local/fsl/bin/oxford_asl: 1176: /usr/local/fsl/bin/oxford_asl: alltis
> [0]= 7: not found
>
> Number of inversion time: 2
> Number of timepoints in data: 88
> Number of repeats in data: 44
>
> I was wondering what shall I put as TIs. I mean my machine parameters are:
>
> - Inversion Time 1: 0.7
> - Saturation Stop Time: 1,6
> - Inversion Time 2: 1,8
>
> Could you please help me with that?
>
> Thanks
>
>
> ---
> Michael Chappell MEng DPhil
>     W: http://www.ibme.ox.ac.uk/qubic
>     T: +44 1865 617657 <+44%201865%20617657>
> Associate Professor, Institute of Biomedical Engineering, University of
> Oxford.
>     http://www.ibme.ox.ac.uk
> Director of Training, EPSRC-MRC CDT in Biomedical Imaging
>       http://www.onbicdt.ox.ac.uk
> Governing Body Fellow, Wolfson College, Oxford.
>     http://www.wolfson.ox.ac.uk
>
> PhysiologyforEngineers.org
> NeuroimagingPrimers.org
>
>
>
>
>
>
>
>