Looks like it has completely failed.  Before you begin, I'd strongly suggest you use CheckReg to show the positioning of your original MRI against that of the SPM templates or any other data that are in MNI space.  The AC should be within about 3-4 cm and the orientation within about 15 to 20 degrees.

Best regards,
-John


On 5 September 2017 at 19:23, Helka Ozelo <[log in to unmask]> wrote:
I´m trying to segment an structural image T1 (by Philips Medical Systems Achieva 3.2.3) using SPM12, but my output files have some problem that I couldn´t understand (attached wc1). Could someone help me, please?