Print

Print


Yes, spots look resolved and data is good. 

On Thu, Aug 17, 2017 at 1:23 PM, Francis E Reyes <[log in to unmask]> wrote:
A long cell axis. Did you make sure those spots are resolved with proper crystal orientation?



On Thu, Aug 17, 2017 at 2:15 PM Vands <[log in to unmask]> wrote:
  Unit Cell:   64.80   64.80  349.38   90.00   90.00  120.0

Molecular weight :15kDa


On Thu, Aug 17, 2017 at 12:25 PM, Ela Govindasamy <[log in to unmask]> wrote:
provide more information: cell parameters scalling details etc

On Thu, Aug 17, 2017 at 1:17 PM, Vands <[log in to unmask]> wrote:
Hi all, 
           
            I have a data set with P622 space group. cell content analysis suggested three molecules in an asymmetric unit.  MR is not giving any solution. I am wondering if there is any NCS. 
I am attaching a self-rotation diagram.  
Inline image 1
Thanks for suggestions. 





--
Vandna Kukshal
Postdoctral Research Associate

Dept. Biochemistry and Molecular Biophysics
Washington University School of Medicine
660 S. Euclid, Campus Box 8231
St. Louis, MO 63110



--
Vandna Kukshal
Postdoctral Research Associate

Dept. Biochemistry and Molecular Biophysics
Washington University School of Medicine
660 S. Euclid, Campus Box 8231
St. Louis, MO 63110