Yes, spots look resolved and data is good. On Thu, Aug 17, 2017 at 1:23 PM, Francis E Reyes <[log in to unmask] > wrote: > A long cell axis. Did you make sure those spots are resolved with proper > crystal orientation? > > > > On Thu, Aug 17, 2017 at 2:15 PM Vands <[log in to unmask]> wrote: > >> Unit Cell: 64.80 64.80 349.38 90.00 90.00 120.0 >> >> Molecular weight :15kDa >> >> >> On Thu, Aug 17, 2017 at 12:25 PM, Ela Govindasamy < >> [log in to unmask]> wrote: >> >>> provide more information: cell parameters scalling details etc >>> >> >>> On Thu, Aug 17, 2017 at 1:17 PM, Vands <[log in to unmask]> wrote: >>> >>>> Hi all, >>>> >>>> I have a data set with P622 space group. cell content >>>> analysis suggested three molecules in an asymmetric unit. MR is not giving >>>> any solution. I am wondering if there is any NCS. >>>> I am attaching a self-rotation diagram. >>>> [image: Inline image 1] >>>> Thanks for suggestions. >>>> >>>> >>> >> >> >> -- >> Vandna Kukshal >> Postdoctral Research Associate >> Dept. Biochemistry and Molecular Biophysics >> Washington University School of Medicine >> 660 S. Euclid, Campus Box 8231 >> St. Louis, MO 63110 >> > -- Vandna Kukshal Postdoctral Research Associate Dept. Biochemistry and Molecular Biophysics Washington University School of Medicine 660 S. Euclid, Campus Box 8231 St. Louis, MO 63110