Print

Print


Anomalous peaks should be doable at shorter wavelengths (if that's all the data there are) as well, depending on data quality. Phaser LLG maps are very sensitive for this. Also by comparing ADPs and local geometry/environment.

JPK

-----Original Message-----
From: CCP4 bulletin board [mailto:[log in to unmask]] On Behalf Of Tim Gruene
Sent: Thursday, January 05, 2017 8:38 AM
To: [log in to unmask]
Subject: Re: [ccp4bb] Detecting chlorides in x-tals

Dear Reza,

if your crystal quality is reasonable, you could collect data at low wavelength and check for the presence of anomalous signal. 
At Cu Kalpha, f"=0.03 for O and and 0.7 for Cl, at 1.8A, its 0.9A. You might be able to see the anomalous signal for Cl in an anomalous omit map.

Best,
Tim

On Thursday 05 January 2017 01:15:01 PM Reza Khayat wrote:
> Hi,
> 
> With the hopes of not reigniting the heated "Chloride or water" CCP4 
> discussion in Jan. 2015, what experimental method is suggested for 
> identifying chlorides in a x-tal?
> 
> Best wishes,
> Reza
> 
> Reza Khayat, PhD
> Assistant Professor
> City College of New York
> Department of Chemistry
> New York, NY 10031
--
--
Paul Scherrer Institut
Dr. Tim Gruene
- persoenlich -
Principal Investigator
Biology and Chemistry
OFLC/102
CH-5232 Villigen PSI

Phone: +41 (0)56 310 5297

GPG Key ID = A46BEE1A