Print

Print


Hi Scott,
		These are the internal representations of the timecourses in MIGP mode. If you want the associated time courses you need to run dual regression of the spatial maps. This will generate least-squares time courses per subject as  part of dr_stage1.

Kind Regards
Matthew

> On 20 Jun 2016, at 23:05, Scott Siegel <[log in to unmask]> wrote:
> 
> I have been able to run single-session ICA correctly, but when I run the multi-session temporal concatenation option with multiple subjects (all resting state fmri from same scanner with equivalent scan conditions) I am getting erroneous results. The timecourse of my components and each of their respective power spectrums are off. Every component is suffering from the same problems. I have attached an image illustrating an example timecourse/powerspectrum that is being output (every component looks like this). I have also attached images of the preprocessing steps I have defined within the Melodic GUI. I would greatly appreciate any incite about why I am getting these results. Thank you in advance for your help.
> <example_timecourse.png><pre_stats.png>