Print

Print


Hi Annie,

to change the colorbar scale of a surface rendering you can have a look
at this:

https://en.wikibooks.org/wiki/SPM/How-to#How_to_choose_the_colour_limits_in_a_surface_rendering.3F

Best regards,
Guillaume.


On 21/01/15 20:47, Anne Racine wrote:
> Hello, Guillaume,
> 
> Thanks so much for getting back to me. After I bring up results, I click
> overlay and render and choose cortex_20484.surf.gii in spm's canonical
> directory. When I type in the syntax you provided in the matlab window
> it gives me the following error:
> 
> 
>>> global st
> 
>>> st.vols{1}.blobs{1}.max = 20;
> 
>>> spm_orthviews('redraw');
> 
> Reference to non-existent field 'bb'.
> 
> 
> Error in spm_orthviews>redraw (line 1075)
> 
> bb   = st.bb;
> 
> 
> Error in spm_orthviews>redraw_all (line 1452)
> 
> redraw(1:max_img);
> 
> 
> Error in spm_orthviews (line 316)
> 
>         redraw_all;
> 
> 
> Thank you very much for your help,
> 
> Annie
> 
> 
> 
> ------
> Annie Racine
> University of Wisconsin
> Neuroscience and Public Policy
> [log in to unmask]
> 608.262.1663
> 
> 
>>>> Guillaume Flandin <[log in to unmask]> 1/21/2015 6:33 AM >>>
> Dear Anne,
> 
> it would help to know which rendering plot you are referring to.
> For the display of the three orthogonal views, you can use the following:
> 
> global st
> st.vols{1}.blobs{1}.max = 20;
> spm_orthviews('redraw');
> 
> Best regards,
> Guillaume.
> 
> 
> On 20/01/15 21:40, Anne Racine wrote:
>> Hello,
>>
>>
>> I would like to change the scale of the colorbar in a rendered result so
>> as to better compare it to another result that is in a different scale.
>> I found this post from last year saying that this was not possible in
>> SPM:
>>
> _/https://www.jiscmail.ac.uk/cgi-bin/webadmin?A2=ind1401&L=SPM&P=R18433&I=-3&d=No+Match%3BMatch%3BMatches./_
> Has
>> there been an update in SPM12 that allows for this adjustment?
>>
>>
>> Thank you,
>>
>> Annie
>>
>>
>>
>> ------
>> Annie Racine
>> University of Wisconsin
>> Neuroscience and Public Policy
>> [log in to unmask]
>> 608.262.1663
>>
>>
> 
> --
> Guillaume Flandin, PhD
> Wellcome Trust Centre for Neuroimaging
> University College London
> 12 Queen Square
> London WC1N 3BG
> 

-- 
Guillaume Flandin, PhD
Wellcome Trust Centre for Neuroimaging
University College London
12 Queen Square
London WC1N 3BG