Hi all and thanks for your input.

I am trying to fix a sugar chain that has consecutive glucoses and I need the angle C-O-C to be as close to 104 degrees as possible keeping alpha bonds between the sugars, so when I do a Real Space Refinement in Coot, the structure gives angles close enough to 104, and the C-O bonds are at acceptable lengths.

Running refmac 5 afterwards always deviates the angles by a great amount to 145 degrees or more for most of the angles. So when I run a Real Space Refinement in Coot for the Refmac5 product, the angles readjust to what is “normal” close to 104.
I have tried restrained and rigid body refinement. And I did external harmonic restraints according to suggestions below by creating a pdb file having only the sentence: "external harmonic residues from 843 E to 850 E sigma 0.02”, 
but I still get very wide angles, any suggestion?

Thanks for your help,
Remie

On Aug 14, 2014, at 11:53 AM, Robert Nicholls <[log in to unmask]> wrote:

> Hi Remie,
> 
> You could always generate self-restraints using one chain or a specific part of a chain using prosmart. These will ensure that the model does not move too far from its current conformation. Let me know if you want help to do this.
> 
> Regards,
> Rob
> 
> 
> On 14 Aug 2014, at 16:11, Remie Fawaz-Touma wrote:
> 
>> Thank you Dr. Murshudov for the information. But please I still need help.
>> 
>> In restrained refinement, I could not find where to enter the residues I want to restrict from moving much. I was only able to find that in rigid body refinement, so I tried it and got a higher R factor than the initial file (before refinement). 
>> 
>> Is it normal to get a higher R factor when doing rigid body refinement?  if not, any suggestion regarding what could be wrong?
>> 
>> Is there a way to restrict one chain or part of a chain from moving much while doing restrained refinement? 
>> 
>> Thank you for any input,
>> 
>> Remie
>> 
>> On Aug 13, 2014, at 10:48 AM, Garib Murshudov <[log in to unmask]> wrote:
>> 
>>> Hi Remie,
>>> 
>>> You can add harmonic restraints for parts you do not want to move too much. Instructions could be found here:
>>> http://www2.mrc-lmb.cam.ac.uk/groups/murshudov/content/refmac/refmac_keywords.html#Harmonic
>>> 
>>> 
>>> Regards
>>> Garib
>>> 
>>> 
>>> On 13 Aug 2014, at 15:44, Remie Fawaz-Touma <[log in to unmask]> wrote:
>>> 
>>>> Hi everyone,
>>>> 
>>>> Does anyone know of a way to refine with CCP4 - Refmac5 (restrained refinement is what I do) fixing a part of the the ligand?
>>>> 
>>>> Thank you very much for your input,
>>>> 
>>>> Remie
>>> 
>>> Dr Garib N Murshudov
>>> MRC-LMB
>>> Francis Crick Avenue
>>> Cambridge 
>>> CB2 0QH UK
>>> Web http://www.mrc-lmb.cam.ac.uk, 
>>> http://www2.mrc-lmb.cam.ac.uk/groups/murshudov/
>>> 
>>> 
>>> 
>> 
>