Dear SPM experts,

I have a question about how to convert data to images in SPM using the  
batch. When I use the GUI in SPM8 to convert epoched data to images I  
get an NIfTI image for each trial. In SPM12b the batch (scalpxtime  
mode) writes only a single *.nii file for each condition. Using these  
nii-files for a t-test leads to a warning message that repeats  
indefinitely:

Warning: Returning NaN for out of range arguments
> In spm_Tcdf at 91
   In spm_ECdensity at 38
   In spm_P_RF at 63
   In spm_uc_RF at 38
   In spm_uc at 31
   In spm_getSPM at 782
   In spm_results_ui at 261

I am also missing the option to interpolate bad channels in the SPM12b batch.