Hi Mark,I have thought that 0 was legal value because if i put my cursor on "Resampling resolution (mm)" box in registration tab of Melodic gui, this message appears:
"If this is set to 0, resampling of your data in standard space (e.g. for multi-subject analysis) will be applied at the resolution of the chosen standard space reference image."
I will set 2 mm.
Thanks
Serena.
On Wed, Apr 30, 2014 at 11:38 AM, Mark Jenkinson <[log in to unmask]> wrote:
Hi,
Why did you enter zero for the resampling resolution?This is going to cause an error.This controls the voxel size for your data, with typical values between 4mm and 2mm (much more memory required for 2mm).
All the best,Mark
On 28 Apr 2014, at 15:07, sere f <[log in to unmask]> wrote:
Dear FLS users,
I have run temporal concatenation ICA. I have 32 subjects and in Registration tab I set:
Main structural image: Normal search, 6 dofStandard Space: Normal search, 12 dofNonlinear: warp resolution (mm) 10Resampling resolution (mm) 0
I get this error:
FATAL ERROR ENCOUNTEREDCannot open volume /home/fabbri/SLI_RS/Subject1/RS/RS_c_18pz-14cnt_NLR.ica/reg_standard/bg_image for reading!while executing"if { [ catch {
for { set argindex 1 } { $argindex < $argc } { incr argindex 1 } {switch -- [ lindex $argv $argindex ] {
-I {incr argin..."(file "/usr/share/fsl/5.0/bin/feat" line 119)
Effectively bg_image.nii.gz and standard.nii.gz are not present in the reg_standard directory for all subjects.
Why not? Any idea?
Thank you in advance.
Serena