Hard to tell. What do you see when you look on the images at the scanner or
in your PACS system?
Have you tried MRIConvert (http://lcni.uoregon.edu/~jolinda/MRIConvert/) or
mri_convert in freesurfer?
Cheers,
Andreas

Von:  Andreas Lidström <[log in to unmask]>
Antworten an:  FSL - FMRIB's Software Library <[log in to unmask]>
Datum:  Donnerstag, 24. April 2014 22:10
An:  <[log in to unmask]>
Betreff:  Re: [FSL] Fieldmap question

This is from a GE Discovery 3T scanner.
I used dcm2nii to convert it into nifti and this produces 4 images like the
one I attatched + 2 phase images that are allso "double" like this.


2014-04-24 20:26 GMT+02:00 Andreas Bartsch <[log in to unmask]>:
> Hi,
> 
> no ­ this does not look right.
> Which scanner are the data from and how did you convert the DICOMs into NIFTI?
> Cheers,
> Andreas
> 
> Von:  Andreas Lidström <[log in to unmask]>
> Antworten an:  FSL - FMRIB's Software Library <[log in to unmask]>
> Datum:  Donnerstag, 24. April 2014 17:31
> An:  <[log in to unmask]>
> Betreff:  [FSL] Fieldmap question
> 
> Hello,
> 
> I have real and imaginary field maps with separate magnitude images, but all
> of them are "double" (two brain stacked onto of each other)
> 
> 1. Why is this?
> 
> 2 Should I combine them somehow before continuing with BET and further field
> map processing?
> 
> cheers