Dear Charline,

In general in beamforming you might run into more trouble because of using too short window and not having enough data than by making the window too long. But perhaps a justified choice of something in the middle would be the best option. See http://www.ncbi.nlm.nih.gov/pubmed/18155612 for in depth discussion of these issues.

Best,

Vladimir


On Thu, Jan 9, 2014 at 3:56 PM, Urbain Charline <[log in to unmask]> wrote:
Dear Vladimir,

I am running a MEG study using vectorial beamformer source reconstruction. As it is often advise to reconstruct sources on smaller time windows  (e.g. 350-400msec) instead of on the whole epoch, I was wondering if, in this case, we also should compute the covariance matrix on the same short time window that we have reconstructed (e.g. 350-400msec) or rather on the whole epoch (-200-1200 msec) ? 

Thank you very much for your help,
Happy new year!

Charline 


Department of Diagnostic Imaging – Research

The Hospital for Sick Children (SickKids)
555 University Ave.Toronto, M5G 1X8

Tel: 416-813-7654-309118
Email: [log in to unmask]" target="_blank">[log in to unmask]