Hi Cedric,

Thanks and I think the error is gone now. Can I ask a question. After selecting the SPM mat file, there is another window that asked for selecting an labelised atlas. I selected the atlas provided with aal. Is this correct?

Is there any other atlas ( for example Broadman areas )  that I can selcet instead of the atlas they provided ?

Thanks

Aser


On Mon, Sep 30, 2013 at 10:14 AM, Koolschijn, Cédric <[log in to unmask]> wrote:
Hi Aser,

This is a known error.
Remove the 2nd "EN" in [P Pn Em En EN] in both files, and you'll be fine.

Cheers
Cédric

-----Original Message-----
From: fMRI <[log in to unmask]>
Reply-To: fMRI <[log in to unmask]>
Date: Monday, September 30, 2013 11:03 AM
To: "[log in to unmask]" <[log in to unmask]>
Subject: [SPM] AAL error spm

>Hi all,
>
>
>I am trying to use aal ( your software). I never have had a luck of
>running the software. Every time I run it I face this message :
>
>>> aal
>    SPM computation                 :                        ...done
>Error using spm_P
>Too many output arguments.
>
>Error in gin_list_dlabels (line 233)
>[P Pn Em En EN] =
>spm_P(1,k,u,df,STAT,R,n,S);
>
>Error in gin_dlabels (line 19)
>gin_list_dlabels('List',xSPM);
>
>Error while evaluating uicontrol Callback
>
>>>
>
>I do not know why or how I should solve it.
>
>Can you please help me?
>
>Thanks
>
>Aser