Hi Pieter,

so your global orientation looks ok, but your origin seems off. The 
quickest way to correct this (in my humble opinion) is the option within 
vbm8 to reset the origin using the center of mass of the largest 
cluster. Works for me and is (hear, hear :) completely automated. Select 
vbm8, Extended tools, Set origin using center of mass.

Good luck,
Marko

Pieter Vandemaele wrote:
> Thanks for the feedback.
> The screenshots were taken with MRICRON.
> This is the result with CheckReg in spm.
>
>
> I did not check out all anatomicals, but it would be a huge burden to
> adjust all subjects manually.
> I normalised the same data with the Normalisation module and did not
> have to reorient the images. Normalisation with the Segment module fails.
> Do you have suggestions to do this fast?
> Thx
>
> Pieter
>
> Op 29/01/2013 11:38, Marko Wilke schreef:
>> Pieter,
>>
>> I would expect that they are all looking into the wrong direction :)
>> but I suggest using spm to check that. If you first call up one of the
>> templates coming with spm, and then your image, they should look
>> similar with regard to their overall orientation. If not so, you can
>> use the pitch, roll, yaw fields to enter multiples (or halves) of pi
>> to reorient your image. Once you're happy with the result, you can
>> apply the transformation to all your images, using "reorient images".
>> This changes the header, so you may want to make sure you have backups
>> first.
>>
>> Cheers,
>> Marko
>>
>>
>>
>> Pieter Vandemaele wrote:
>>> Dear SPM'ers,
>>>
>>> I used the Segment module to segment and normalize anatomical scans and
>>> got strange results, see attachments.
>>> Is this due to the origin localisation?
>>> What is the easiest way to deal with this? I have 80 subjects so a
>>> (semi)automatic solution would be ideal.
>>>
>>> Best
>>>
>>> Pieter
>>
>
>
> --
> Re: Netwerk MR afdeling UZGent
>
> *Pieter Vandemaele, *MSc-Ing
> *GIfMI Site Manager*
> Ghent Institute for Functional and Metabolic Imaging
> MR Department -1K12
> Ghent University Hospital
> De Pintelaan 185
> 9000 Ghent - BELGIUM
>
> [log in to unmask] <mailto:[log in to unmask]> 	tel: +32
> (0)9 332 48 20
> http://gifmi.ugent.be 	fax: +32 (0)9 332 49 69
>
>
>
>

-- 
____________________________________________________
PD Dr. med. Marko Wilke
  Facharzt für Kinder- und Jugendmedizin
  Leiter, Experimentelle Pädiatrische Neurobildgebung
  Universitäts-Kinderklinik
  Abt. III (Neuropädiatrie)


Marko Wilke, MD, PhD
  Pediatrician
  Head, Experimental Pediatric Neuroimaging
  University Children's Hospital
  Dept. III (Pediatric Neurology)


Hoppe-Seyler-Str. 1
  D - 72076 Tübingen, Germany
  Tel. +49 7071 29-83416
  Fax  +49 7071 29-5473
  [log in to unmask]

  http://www.medizin.uni-tuebingen.de/kinder/epn/
____________________________________________________