Print

Print


Dear Syu-Jyun,

No you need at least 3 different b-values. A typical protocols for diffusion kurtosis imaging can be found, e.g., on this page: http://academicdepartments.musc.edu/cbi//dki.

Best,
Siawoosh


-------- Original-Nachricht --------
> Datum: Sun, 20 Jan 2013 07:27:45 +0000
> Von: Peng Syu-Jyun <[log in to unmask]>
> An: "[log in to unmask]" <[log in to unmask]>
> Betreff: [SPM] Can my DTI data product diffusional kurtosis imaging ?

> Dear exports
> Can my DTI data product diffusional kurtosis imaging ?
> My DTI datasets were acquired with 25 diffusion-weighted echo-planar
> images (EPI) (b = 1000 s/mm2) and a null image (b = 0 s/mm2). The acquisition
> parameters of 34 slices were: TR = 8000 ms, TE = 82.4 ms, voxel size 0.98 ×
> 0.98 × 3 mm3, and FOV = 25 × 25 cm2.
> Best regards,
> Syu-Jyun


-- 
Dr. Siawoosh Mohammadi 
Post Doctoral Research Fellow 
Wellcome Trust Center for Neuroimaging 
Institute of Neurology 
University College London 
12 Queen Square 
London WC1N 3BG 
United Kingdom 

Tel. +44-20-344-84368, (internal ext 84368) 
Fax. +44-20-7813-1420 

[log in to unmask]