Print

Print


Thanks Sir,

It worked

On Tue, Jan 15, 2013 at 2:12 PM, Christian F. Beckmann <
[log in to unmask]> wrote:

> Are these results generated from group ICA? If so, they are already in
> MNI152, though potentially at a different voxel size (if you left the
> 'resampling resolution' in the melodic GUI at default). In this case simply
> run
>
> flirt -in melodic_IC -ref $FSLDIR/data/standard/MNI152_T1_2mm \ -out
> melodic_IC_hr -applyisoxfm 2 -init
>
> to initialise flirt using the identity matrix (files will not be
> transformed) and get a resampling into 2mm isotropic MNI152.
>
> hth
> Christian
>
>
> On 21 Dec 2012, at 06:48, Himanshu Joshi <[log in to unmask]> wrote:
>
> > Thanks of your reply,
> > But even for running a linear registration to standard space also
> follows the same pattern (see attached image)
> >
> > and regarding apply wrap application if I applywrap on MNIstandard
> template using this command.
> > applywarp -i $FSLDIR/data/standard/MNI152_T1_2mm -r example_func \
> --premat=std2exfunc.mat -o lowresmask -d float
> >
> > Can I be able to overlap melodic_IC file on the wrapped image I dont
> think so?
> >
> >
> > Please provide the hint to write the command line to proceed
> >
> > On Fri, Dec 21, 2012 at 5:42 AM, Mark Jenkinson <
> [log in to unmask]> wrote:
> > Hi,
> >
> > Did you run nonlinear registration to standard space?
> > If so then you need to use applywarp and the warp outputs to do the
> transformation.
> >
> > All the best,
> > Mark
> >
> >
> >
> > On 19 Dec 2012, at 11:00, Himanshu Joshi <[log in to unmask]> wrote:
> >
> >> Dear FSL experts,
> >>
> >> I had tried using this command
> >> flirt -in melodic_IC -ref $FSLDIR/data/standard/MNI152_T1_2mm \ -out
> melodic_IC_hr -applyxfm -init ../reg/example_func2standard.mat
> >> There is a change in field of view in melodic_hr file.
> >>
> >>
> >> and the activations in the file (melodic_hr)seems to be shifted towards
> left after application of the above mentioned command they are not
> overlapping to standard template MNI152_T1_2mm
> >>
> >> If I apply same command to standard template the activations in
> melodic_hr file exactly matches but the FOV of standard template also
> changes and the axial and coronal images seems to be cut of a little
> because of modified FOV
> >>
> >> If you can please suggest some solution to the problem
> >>
> >> --
> >> Himanshu Joshi
> >>
> >
> >
> >
> >
> > --
> > Himanshu Joshi
> > M.Tech. Cognitive & Neuroscience.
> > Senior Research Fellow
> > Department of Psychiatry
> > NIMHANS, Bangalore
> >
> > http://mbial.weebly.com/himanshu-joshi.html
> > <melodicfile.jpg>
>



--
*Himanshu Joshi*
M.Tech. Cognitive & Neuroscience.
Senior Research Fellow
Department of Psychiatry
NIMHANS, Bangalore

http://mbial.weebly.com/himanshu-joshi.html