Print

Print


Hi Lisa,
 
The problem you have can be very tricky. Here my comments:
 
-What do you mean by "I can not solve the structure by molecular replacement"?. Moleculare replacement programs usually produce some solution, even if it is wrong. Do the R-factors stay around 50%, is the electron density very bad? If you do not get a solution at all, the solution might be rejected because of clashes. In this case you may want to cut out some variable loops from the model or increase the maximum number of allowed clashes.
-What does the Matthews number tell you? If you get a very dense crystal packing even with one molecule in the asymmetric unit, you most likely have twinning.
-3.3 Å means rather poor data. This means that the statistics you get on your space group and on the twinning will be tentative and you have to test all possibilities. Also you may have pseudo crystallographic NCS making the apparent space group look different from the true space group. This means that in molecular replacement, you have to test all possibilities, e.g. P622, P6122, P6222, P6322 etc. Most molecular replacement programs have an option to automatically test them all.
-Considering twinning, you have to process the data in the lower symmetry space group, presumably P6 and submit the data to a twin server, as Fred suggested. I would also run molecular replacement on the lower symmetry data. Even with perfect twinning, one usuallly gets two solutions, corresponding to the two twin domains.
 
Good luck!
Herman


From: CCP4 bulletin board [mailto:[log in to unmask]] On Behalf Of LISA
Sent: Tuesday, January 22, 2013 7:25 AM
To: [log in to unmask]
Subject: [ccp4bb] perfect twin

Hi all,
Does anyone know how to check a data is twin and how to detwin?
My data is 3.3 A with space group P6222 or P6422? But I can not solve this structue by molecular replacement with the model has 42% sequence identity. I am wondering my data maybe twin.
Thanks
Lisa