Dear Yass,

normally I do not comment on someone's study goals, but now it is too hard to resist.

ICA and GLM are completely different approaches answering completely different research questions about brain function. Why compare the respective results images directly? I cannot think of one useful way to do that. What purpose does that serve? ICA results aren't really activation maps to begin with, but higher dimensional structures best explaining your data.

To me comparing ICA components with GLM activation maps makes as much sense as comparing South African stock prices with the reproduction habits of an amoeba.

Perhaps you have much more detailed comparison in mind that makes sense, and then I apologize beforehand. Love to hear it though.

I'm sorry when I'm sounding pompous... I sincerely hope you can find a way to get your explorations on the right track.

Good luck,

Bas


On 08/03/2012 12:55 PM, Yass. Jd. wrote:
[log in to unmask]" type="cite">

Dear all,

 

I am trying to compare the GLM method with others such as ICA and Hybrid methods. In order to do that, I would like to compare the activation maps produced by these methods.

 

How can I can access the results of SPM (SPM.mat) in a normalized and automatic way to be compared with others activations with a similarity index or something ? Knowing that ICA results will come from another software …

 

I am a beginner in this topic so any help is welcome !

 

Thank you very much  !

Yass JD.



-- 
--------------------------------------------------
Dr. S.F.W. Neggers
Division of Brain Research
Rudolf Magnus Institute for Neuroscience
Utrecht University Medical Center

Visiting : Heidelberglaan 100, 3584 CX Utrecht
           Room B.01.1.03
Mail     : Huispost B01.206, P.O. Box 85500
           3508 GA Utrecht, the Netherlands
Tel      : +31 (0)88 7559609
Fax      : +31 (0)88 7555443
E-mail   : [log in to unmask]
Web      : http://www.neuromri.nl/people/bas-neggers
         : http://www.brainsciencetools.com (CEO)
--------------------------------------------------

De informatie opgenomen in dit bericht kan vertrouwelijk zijn en is uitsluitend bestemd voor de geadresseerde. Indien u dit bericht onterecht ontvangt, wordt u verzocht de inhoud niet te gebruiken en de afzender direct te informeren door het bericht te retourneren. Het Universitair Medisch Centrum Utrecht is een publiekrechtelijke rechtspersoon in de zin van de W.H.W. (Wet Hoger Onderwijs en Wetenschappelijk Onderzoek) en staat geregistreerd bij de Kamer van Koophandel voor Midden-Nederland onder nr. 30244197.

Denk s.v.p aan het milieu voor u deze e-mail afdrukt.


This message may contain confidential information and is intended exclusively for the addressee. If you receive this message unintentionally, please do not use the contents but notify the sender immediately by return e-mail. University Medical Center Utrecht is a legal person by public law and is registered at the Chamber of Commerce for Midden-Nederland under no. 30244197.

Please consider the environment before printing this e-mail.