Print

Print


Yes - we've just purchased their replacement ; the GA 5000

 

http://www.geotechuk.com/1739.aspx <http://www.geotechuk.com/1739.aspx> 

 

Simon Clark

Pollution Control Division

Public Protection

Environment Department

City & County of Swansea

 

 

 

 

________________________________

From: Contaminated Land Management Discussion List
[mailto:[log in to unmask]] On Behalf Of Jon
Archer
Sent: 17 May 2012 15:33
To: [log in to unmask]
Subject: gas monitoring

 

Good afternoon all.

We are looking to buy a new ground gas monitoring instrument, having
been informed that our GA2000 will no longer be calibrated by the
manufacturer as of March 2013.

I wondered if all concerned are aware of the same issue with their
GA2000, and if you have any suggestions for suitable replacement
instruments for borehole monitoring.

 

Kind regards,

Jon Archer 

Principal Geoenvironmental Engineer
Harrison Group Environmental Limited

Tel: 01603 613111 

Web: www.harrisongroupuk.com

 

Registered in England No. 1306165

Registered Office: Kimberley Street, Norwich, NR2 2RJ

****Disclaimer****   This email and any attachments are confidential to
the intended recipient and may also be privileged. If you are not the
intended recipient, please delete it from your system and notify the
sender. Internet communications are not secure. Harrison Group
Environmental Ltd. does not accept legal responsibility for the contents
of this message. Any views or opinions presented are those of the author
only and do not necessarily represent those of Harrison Group
Environmental Ltd.