Dear Kie Woo, the template for the low-dimensional spatial normalization approach is the T1.nii image, which can be found in the spm8 templates folder. Regards, Christian ____________________________________________________________________________ Christian Gaser, Ph.D. Departments of Psychiatry and Neurology Friedrich-Schiller-University of Jena Jahnstrasse 3, D-07743 Jena, Germany Tel: ++49-3641-934752 Fax: ++49-3641-934755 e-mail: [log in to unmask] http://dbm.neuro.uni-jena.de On Thu, 29 Mar 2012 18:56:36 +0100, Kie Woo Nam <[log in to unmask]> wrote: >Dear experts, > >I would much appreciate some advice about VBM8. > >Under the "Extended options --> Spatial normalization", I see the following options. > >1. "High-dimensional: Dartel" >2. "Low-dimensional: SPM default" > > >I see that the "High-dimensional: Dartel" uses "Template_1_IXI550_MNI152.nii". But, I can't find which template is used for the other one. > >So could someone please tell me which template is used for "Low-dimensional: SPM default"? > >Thank you very much for your help in advance. > >Kie Woo > > > > >Kie Woo Nam >Postgraduate Research Student >Division of Psychological Medicine >Department of Psychosis Studies >Institute of Psychiatry, King’s College London >De Crespigny Park, Denmark Hill >London SE5 8AF, UK >Tel: +44 (0)20 7848 0061