Dear Vladimir, Dear SPM-M/EEG experts, I have two questions concerning source waveform extraction. I made a source reconstruction with these parameters : type: 'GS' woi: [650 900] Han: 1 lpf: 0 hpf: 128 pQ: {} trials: {'1' '2' '3' '4' '5' '6'} modality: {'MEGPLANAR' 'MEG'} smooth: 0.6000 xyz: [0 0 0] rad: 128 scale: [6.1519e+07 -3.7706e+09] M: [8196x176 double] J: {1x6 cell} Y: {1x6 cell} L: [176x8196 double] qC: [8196x1 double] qV: [63x63 double] T: [63x10 double] U: {[107x204 double] [69x102 double]} Is: [8196x1 double] It: [1x63 double] Ic: {[1x204 double] [1x102 double]} Nd: 8196 pst: [1x63 double] dct: [1x63 double] F: -8.9217e+03 ID: 314.5232 R2: 94.7399 VE: 94.2432 My first question is: when I used the code that you provided in a previous mail (31/12/2012, see attachment 1) to extract the source waveform in a particular MNI coordinate (28, 14 -28), it gives me the temporal sequence on the interest window (650-900, see attachment 2), but I would have preferred to plot results on all the epoch (0-900ms), is that possible? Secondly, I found this MNI coordinate of interest (28, 14 -28) at the group level (by producing separate source reconstructions for each participant. These reconstructions were then analyzed by proportionally scaling the results and submitting the reconstructions to the general linear models and contrasts of interest). I was wondering what should be the best way to represent the sourcewave of this specific result/activation? Should I reconstruct the grand average and plot it sourcewave ? Thank you very much for your help, best, Charline