Print

Print


Hi,
Solved. Thank you so much!
Kind regards,
Jose Paulo Santos


On Tue, 24 Jan 2012 12:05:26 +0000, Stephen Smith <[log in to unmask]> wrote:

>Hi - if you edit
>$FSLDIR/tcl/glm.tcl
>and change the following line, you can change this limit.
>LabelSpinBox  $w.npts -textvariable fmri(npts) -label " # timepoints " -range {2 10000 1} -command "$w.npts.spin.e validate; glm:updatenpts $w" -modifycmd "glm:updatenpts $w"
>
>Cheers.
>
>
>
>
>
>On 23 Jan 2012, at 02:41, Jose Paulo Santos wrote:
>
>> Dear experts,
>> I have an fMRI experiment with 22 subjects, each with 485 volumes. I�m analyzing group data with Multi-session Tensor-ICA option at MELODIC, which yields 65 independent components. Each IC has its own timecourse, which in this experiment corresponds to 10,670 timepoints. Using the file melodic_mix as data source, I�m running the command fsl_glm to statistically link each IC to the most significant EVs. To generate EVs� timecourses I�m using GLM Setup.
>> The problem that I�m facing now is the existence of a ceiling at 10,000 timepoints in GLM Setup. As I have 10,670 the GUI automatically changes the value to 10,000 again and� I can�t generate my EVs (or I only generate 10,000 timepoints).
>> Am I doing something wrong? Is there a command line version for GLM Setup that has no ceiling? Is there any way to overcome this issue?
>> Kind regards,
>> Jose Paulo Santos
>> 
>
>
>---------------------------------------------------------------------------
>Stephen M. Smith, Professor of Biomedical Engineering
>Associate Director,  Oxford University FMRIB Centre
>
>FMRIB, JR Hospital, Headington, Oxford  OX3 9DU, UK
>+44 (0) 1865 222726  (fax 222717)
>[log in to unmask]    http://www.fmrib.ox.ac.uk/~steve
>---------------------------------------------------------------------------
>
>
>
>