Hi, Solved. Thank you so much! Kind regards, Jose Paulo Santos On Tue, 24 Jan 2012 12:05:26 +0000, Stephen Smith <[log in to unmask]> wrote: >Hi - if you edit >$FSLDIR/tcl/glm.tcl >and change the following line, you can change this limit. >LabelSpinBox $w.npts -textvariable fmri(npts) -label " # timepoints " -range {2 10000 1} -command "$w.npts.spin.e validate; glm:updatenpts $w" -modifycmd "glm:updatenpts $w" > >Cheers. > > > > > >On 23 Jan 2012, at 02:41, Jose Paulo Santos wrote: > >> Dear experts, >> I have an fMRI experiment with 22 subjects, each with 485 volumes. I�m analyzing group data with Multi-session Tensor-ICA option at MELODIC, which yields 65 independent components. Each IC has its own timecourse, which in this experiment corresponds to 10,670 timepoints. Using the file melodic_mix as data source, I�m running the command fsl_glm to statistically link each IC to the most significant EVs. To generate EVs� timecourses I�m using GLM Setup. >> The problem that I�m facing now is the existence of a ceiling at 10,000 timepoints in GLM Setup. As I have 10,670 the GUI automatically changes the value to 10,000 again and� I can�t generate my EVs (or I only generate 10,000 timepoints). >> Am I doing something wrong? Is there a command line version for GLM Setup that has no ceiling? Is there any way to overcome this issue? >> Kind regards, >> Jose Paulo Santos >> > > >--------------------------------------------------------------------------- >Stephen M. Smith, Professor of Biomedical Engineering >Associate Director, Oxford University FMRIB Centre > >FMRIB, JR Hospital, Headington, Oxford OX3 9DU, UK >+44 (0) 1865 222726 (fax 222717) >[log in to unmask] http://www.fmrib.ox.ac.uk/~steve >--------------------------------------------------------------------------- > > > >