Dear all,
Just as a historic reminder, I feel necessary to mention a key article on refinement, written by R.Aragwal (1978) in Acta Cryst A, where he used 1- and 2-gaussian atomic factors (obviously, less precise
that 4 gaussians + constant but allowed him at that moment to accelerate as much as possible the calculations).
With best regards,
Sacha Urzhumtsev
De : CCP4 bulletin board [mailto:[log in to unmask]]
De la part de Pavel Afonine
Envoyé : jeudi 3 novembre 2011 04:40
À : [log in to unmask]
Objet : Re: [ccp4bb] atomic scattering factors in REFMAC
Continuing on the subject, as far as I know there are at least three flavors of form-factors currently used in refinement programs:
"4 gaussian plus const":
International Tables for Crystallography (1992)
"5 gaussian plus const":
D. Waasmaier & A. Kirfel. Acta Cryst. (1995). A51, 416-431. "New analytical scattering-factor functions for free atoms and ions"
"n-gaussian" (n determined dynamically)
Grosse-Kunstleve RW, Sauter NK & Adams PD. Newsletter of the IUCr Commission on Crystallographic Computing 2004, 3:22-31. "cctbx news"
All three are available in PHENIX (the 3rd is used by default), and I presume the first one is used in CNS and Refmac, if I remember correctly (the authors of respective programs please correct me).
Pavel