Print

Print


Dear Refmac users,

I noticed that if I refine a structure containing SeMet, then Se atoms usually have big negative (red) peeks of difference map and high B-factors. As I understand from the diffraction theory and from some discussions at CCP4bb, that may result because in REFMAC the atomic scattering factors are internally coded for copper radiation (CuKa).
I tried to use keyword "anomalous wavelength 0.9683" and found that with this keyword I had different values of coefficient c for Se, Mn, and P as shown in REFMAC log-file:

loop_
     _atom_type_symbol
     _atom_type_scat_Cromer_Mann_a1
     _atom_type_scat_Cromer_Mann_b1
     _atom_type_scat_Cromer_Mann_a2
     _atom_type_scat_Cromer_Mann_b2
     _atom_type_scat_Cromer_Mann_a3
     _atom_type_scat_Cromer_Mann_b3
     _atom_type_scat_Cromer_Mann_a4
     _atom_type_scat_Cromer_Mann_b4
     _atom_type_scat_Cromer_Mann_c

  N     12.2126   0.0057   3.1322   9.8933   2.0125  28.9975   1.1663   0.5826 -11.5290
  C      2.3100  20.8439   1.0200  10.2075   1.5886   0.5687   0.8650  51.6512   0.2156
  H      0.4930  10.5109   0.3229  26.1257   0.1402   3.1424   0.0408  57.7997   0.0030
  O      3.0485  13.2771   2.2868   5.7011   1.5463   0.3239   0.8670  32.9089   0.2508
  SE    17.0006   2.4098   5.8196   0.2726   3.9731  15.2372   4.3543  43.8163  -1.0329
  MN    11.2819   5.3409   7.3573   0.3432   3.0193  17.8674   2.2441  83.7543   1.3834
  P      6.4345   1.9067   4.1791  27.1570   1.7800   0.5260   1.4908  68.1645   1.2650

As a result, red peeks around Se are significantly lower, Se B-factors are a bit smaller (like 25.6 and 23.1), and Rf is lowered by a bit more than 0.1% with the same input files.

That looks pretty good. Still, I want to ask your opinion on the following:

1) Is it proper way to specify atomic scattering factors? I found this keyword under REFMAC documentation topic "Simultaneous SAD experimental phasing and refinement" and Im not sure if I change something else when I specify the keyword. I dont have separate F+, F- and corresponding SIGF+, SIGF- in my mtz, so SAD experimental phasing should not go.
2) Do you think it is safe to specify this keyword for every structure under refinement? Can it have some drawbacks (except wrong wavelength)?
As I understand, the theoretical Cromer_Mann curve can be different from experimental, but still it is better than not to change scattering factor at all.

Thank you very much!!

With best regards,
Ivan Shabalin, Ph.D.
Research Associate, University of Virginia
4-224 Jordan Hall, 1340 Jefferson Park Ave.
Charlottesville, VA 22908