On 12 Sep 2011, at 10:01, Liliana R. Demenescu wrote:
> Hi all,
>
> I am a newbie in dti analysis and fsl and I any suggestion is appreciate.
> I have been trying to find an ansswer to my problem looking through the archive but couldn't find it.
>
> I have for one session of dti data two folders, one contains the b0 image and the other one holds the diffusion images. The problem is that the b0 image has a different resolution (96x218) than the diffusion files (104x128). These images were acquired on Siemens 4T.
> What do you think is the best way to deal with this kind of data?
> I was thinking to do first normalization so I can have the same size for b0 as for diffusion images. Would this be a problem? After this, to concatenate these files (b0 and diffusion images). As I saw, in fsl for eddy correction I cannot choose more than one file therefore I need to have the b0 image in the same file with diffusion images.
>
> Thank you in advance!
>
> Best wishes,