Hi Tim,
I am worry about if there is any problem just scale the two sets together in HKL2000, since they had different exposure time.
Will the program match them?
thanks,
Pengfei
At 2011-05-31 02:50:41,"Tim Gruene" <[log in to unmask]> wrote:
>Dear pengfei,
>
>you do not need to use mosflm if you want to scale the datasets with scala. You
>can use scalepack2mtz (available from ccp4i -> Program List) to convert the two
>sca-files to mtz-format and then use scala for scaling.
>Maybe HKL2000/scalepack can scale the files for you if you integrate them both
>in the same run (load both data sets, and HKL2000 will integrate both data
>sets).
>
>Tim
>
>On Tue, May 31, 2011 at 02:40:49AM +0800, Pengfei Fang wrote:
>> Hi David,
>>
>> Thanks for your help. I just scaled the two data sets independently using HKL2000.
>> And, I don't know how to set reference in HKL2000 or CCP4.
>> If using CCP4, should I also use imosflm to do integrate?
>>
>> thanks,
>> pengfei
>>
>>
>> At 2011-05-31 02:32:03,"David Veesler" <[log in to unmask]> wrote:
>> Hi Pengfei,
>> you can combine your files using pointless but it is unclear to me based on your message if you have scaled independently the two data sets or not.
>> You should scale these two data sets together using one as reference (doable using XSCALE or SCALA...).
>> Cheers
>> David
>>
>>
>> Le 30 mai 2011 à 11:13, Pengfei Fang a écrit :
>>
>> Dear All,
>>
>> I have two data sets from one crystal.
>> One had short exposures to keep the low resolution reflections from saturating. The other had long exposure to get high resolution data.
>> I am wondering how two merge these two data sets into one file that I can use for refinement.
>>
>> The two sets already scaled by HKL2000. Now I have two .sca files.
>>
>> Thanks a lot!
>> Pengfei Fang
>>
>>
>>
>> --
>> This message has been scanned for viruses and
>> dangerous content byMailScanner, and is
>> believed to be clean.
>>
>>
>>
>> --
>> This message has been scanned for viruses and
>> dangerous content byMailScanner, and is
>> believed to be clean.
>
>--
>--
>Tim Gruene
>Institut fuer anorganische Chemie
>Tammannstr. 4
>D-37077 Goettingen
>
>phone: +49 (0)551 39 22149
>
>GPG Key ID = A46BEE1A
>