Hi Angela,

My colleagues and I at UCSF published a letter to Clinical Chemistry on 
this topic  some time ago:

Canfell, P.C., Binder, S.R. and Khayam-Bashi, H.  “Pediatric Reference 
Intervals for Normetanephrine/Metanephrine (Letter).”  Clinical Chemistry 
1986; 32:222-223.

As you appreciate, this kind of study is very hard to perform, which is 
why there have been few efforts to repeat it.  The method used was GC/MS, 
which in my hands agreed with HPLC within 15-20%, so this offers some 
guideline as to what you might expect.  The advantage of metanephrines for 
spot urine is that output and stability do not depend on pH, so I believe 
you are making the right move.


Regards, 

Steven R. Binder
Director, Technology Development
Clinical Diagnostics Group
Bio-Rad Laboratories
4000 Alfred Nobel Drive
Hercules CA 94547
Phone :   510-741-4603
e-mail:     [log in to unmask]




From:   Kremmyda Angela <[log in to unmask]>
To:     <[log in to unmask]>
Date:   03/28/2011 08:32 AM
Subject:        Urine mets to creatinine ratio
Sent by:        Clinical biochemistry discussion list 
<[log in to unmask]>


Dear all,
 
We are about to move from measuring urine catecholamines to (urine) 
metanephrines for screening for phaeo. Currently we ask for spot urine(s) 
and use the ratio to creatinine and we’d like to keep it like that for the 
metanephrines (instead of having 24 h urine collections). Our problem is 
there is no reference range provided by the manufacturer for the ratio and 
we’re finding it very difficult to find any other data. Are there any 
users out there that use the ratio to creatinine and would be willing to 
share their normal range? Our method is HPLC.
Any help would be very welcome (we are getting a bit desperate…).
 
Thanks in anticipation
 
Angela 
 
Angela Kremmyda
Senior Biochemist
 
Dept of Clinical Biochemistry
Royal Shrewsbury Hospital
Mytton Oak Road
Shrewsbury
SY3 8XQ
 
Tel:  01743 261158
Fax: 01743 261159
 
This message may contain confidential information. If you are not the 
intended recipient please inform the sender that you have received the 
message in error before deleting it. Please do not disclose, copy or 
distribute information in this e-mail or take any action in aliance on its 
contents: to do so is strictly prohibited and may be unlawful.
 
------ACB discussion List Information-------- This is an open discussion 
list for the academic and clinical community working in clinical 
biochemistry. Please note, archived messages are public and can be viewed 
via the internet. Views expressed are those of the individual and they are 
responsible for all message content. ACB Web Site http://www.acb.org.uk 
Green Laboratories Work http://www.laboratorymedicine.nhs.uk List Archives 
http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html List Instructions 
(How to leave etc.) http://www.jiscmail.ac.uk/ 


------ACB discussion List Information--------
This is an open discussion list for the academic and clinical community working in clinical biochemistry.
Please note, archived messages are public and can be viewed via the internet. Views expressed are those of the individual and they are responsible for all message content.
ACB Web Site
http://www.acb.org.uk
Green Laboratories Work
http://www.laboratorymedicine.nhs.uk
List Archives
http://www.jiscmail.ac.uk/lists/ACB-CLIN-CHEM-GEN.html
List Instructions (How to leave etc.)
http://www.jiscmail.ac.uk/