Print

Print


Hi Sebastiano,

Just to add to Dima's response, I've used ceramic hydroxyapatite column and
got great results separating 2 very large membrane proteins complexes that
eluted together in DEAE/Q and ran in similar size range in SEC. One eluted
in 100-200mM KPi and the the other in 300mM+ KPi ~pH 7.4.

-john



On Mon, Nov 29, 2010 at 9:08 AM, Sebastiano Pasqualato <
[log in to unmask]> wrote:

> Hi all,
> I read/heard that hydroxyapatite column can be used to purify proteins,
> getting separation results orthogonal to ion exchange and size exclusion
> chromatography.
> I was wondering if any of you would be kind enough to share her/his
> experience with me, and would suggest vendors and models for such columns.
> Thanks in advance,
> best,
> s
>
> --
> Sebastiano Pasqualato, PhD
> IFOM-IEO Campus
> Dipartimento di Oncologia Sperimentale
> Istituto Europeo di Oncologia
> via Adamello, 16
> 20139 - Milano
> Italy
>
> tel +39 02 9437 5094
> fax +39 02 9437 5990
>