I came across the following warning while working with some (but not all) GE T1 and T2 data: "inconsistent left-right order stored in sform and qform in file "... "Using sform instead of qform values" The dicom data were run through dcm2nii before opening in FSLview. Subjects with the warning do demonstrate a discrepancy between qform and sform matrices. Should I be concerned about this warning? If I remember correctly, GE scanners used to be susceptible to L-R orientation being dependent on what the scanner operator did at the time of acquisition. Is this still true? Any comments are greatly appreciated. Jenifer The fslhd info (tail of the file) for subjects with this warning is appended below: qform_name Scanner Anat qform_code 1 qto_xyz:1 0.937500 0.000000 -0.000000 -116.604500 qto_xyz:2 0.000000 1.500000 -0.000000 -73.582993 qto_xyz:3 0.000000 0.000000 -0.937500 -113.845497 qto_xyz:4 0.000000 0.000000 0.000000 1.000000 qform_xorient Left-to-Right qform_yorient Posterior-to-Anterior qform_zorient Superior-to-Inferior sform_name Scanner Anat sform_code 1 sto_xyz:1 0.937500 0.000000 0.000000 -116.604500 sto_xyz:2 0.000000 1.500000 0.000000 -73.582993 sto_xyz:3 0.000000 0.000000 0.937500 -113.845497 sto_xyz:4 0.000000 0.000000 0.000000 1.000000 sform_xorient Left-to-Right sform_yorient Posterior-to-Anterior sform_zorient Inferior-to-Superior file_type NIFTI-1+ file_code 1 descrip aux_file