On 10 Sep 2009, at 19:29, Pavel Afonine wrote:

Hi Sylvia,

although modern MR programs perform rigid body refinement, it may be worth of giving a try a novel rigid body refinement protocol implemented in phenix.refine (MZ rigid-body refinement protocol), that has very high convergence radius:
J. Appl. Cryst. (2009). 42, 607-615. "Automatic multiple-zone rigid-body refinement with a large convergence radius".

Next step would be to try torsion angle (or Cartesian) simulated annealing refinement. You can also try combining it with real-space refinement. More details: 

If resolution allows, eg better than 2.5 A, good old ARP/wARP will do the trick as well, if the solution is correct.

More details:

http://www.ncbi.nlm.nih.gov/pubmed/18094467?ordinalpos=13&itool=EntrezSystem2.PEntrez.Pubmed.Pubmed_ResultsPanel.Pubmed_DefaultReportPanel.Pubmed_RVDocSum

Tassos




Please let me know if you have questions about the above options, or/and: http://www.phenix-online.org/

Pavel.



On 9/10/09 9:05 AM, Sylvia Fanucchi wrote:
[log in to unmask]" type="cite"><ATT00001.jpg>

Hi everyone

 

I am new to solving crystal structures so apologies for the simple question

 

I am solving a structure using molecular replacement. I have refined my structure with refmac however the R-factor and R-free do not seem to go down with successive rounds of refinement. The initial value was 0.49 (after 20 cycles of rigid body refinement). After analysing the output and a further 20 cycles of refinement, the R-factor is now 0.48. I would like to know if it is ever worthwhile to continue refining a structure when the initial R factors are so high? If so, what could I do to improve the refinement? 

 

Thanks for your suggestions

 

Best regards

Sylvia Fanucchi Ph.D

Protein Structure-Function Research Unit
East Campus, Gate House Room 416
School of Molecular and Cell Biology
University of the 
Witwatersrand
Johannesburg 2050
South Africa

Tel: +27 (11) 717-6348 Fax: +27 (11) 717-6351 
E-mail: 
[log in to unmask] 

 

This communication is intended for the addressee only. It is confidential. If you have received this communication in error, please notify us immediately and destroy the original message. You may not copy or disseminate this communication without the permission of the University. Only authorized signatories are competent to enter into agreements on behalf of the University and recipients are thus advised that the content of this message may not be legally binding on the University and may contain the personal views and opinions of the author, which are not necessarily the views and opinions of The University of the Witwatersrand, Johannesburg. All agreements between the University and outsiders are subject to South African Law unless the University agrees in writing to the contrary.