HI - have you tried using the model Wizard, as suggested in the  
manual? This will do the basic setup for you.
Steve.


On 5 Jun 2009, at 19:03, Nicole Pelot wrote:

> Hi,
>
> I have read the FEAT Perfusion documentation quite a few times now,  
> but I
> still cannot figure out how to properly set up my EVs. I have a  
> block design
> task: 56s/block, 7 blocks, alternating between rest and active  
> (start &
> finish with rest).
>
> My main issue is with EV1. It clearly states that we should be  
> modeling
> *rest* times, but that leads me to think of a block design with 0's  
> for
> active and 1's for rest. However, the sample design seems to show  
> all 1's
> for EV1. Also, what convolution should be applied? None?
>
> I've structured EV2 as I always do to correspond to my block design.  
> (On:
> 56s; Off: 56s; Convolution: Double gamma).
>
> EV3, I chose "Interaction", and I made the mean of EV1 zero (but the  
> min of
> EV2).
>
> Thank you,
>
> Nicole
>


---------------------------------------------------------------------------
Stephen M. Smith, Professor of Biomedical Engineering
Associate Director,  Oxford University FMRIB Centre

FMRIB, JR Hospital, Headington, Oxford  OX3 9DU, UK
+44 (0) 1865 222726  (fax 222717)
[log in to unmask]    http://www.fmrib.ox.ac.uk/~steve
---------------------------------------------------------------------------