Hi Thiyagarajan,

the latest version of PHENIX has a command line tool called 
"phenix.real_space_correlation", that for each atom or residue computes:

- map CC (where a user can define any map types, the default: 2mFo-DFc 
and Fc maps),
- 2mFo-DFc map value at atom center,
- mFo-DFc map value at atom center.

Please let me know if you have question,
Pavel.


On 4/20/09 3:47 AM, S. Thiyagarajan wrote:
> Dear CCP4 users
>
> Is there any easy way of calculating the peak height / number of 
> electrons at a given position, say a mouse click point in coot.
>
> Is there any formula to calculate the number of electrons based on 
> sigma level and peak height, as given in difference map peaks in coot.
>
> I have some peaks in my map which take water or sodium/magnesium or 
> chlorine atom with out giving out any positive or negative density 
> upon further refinement.
>
> The asymmetric unit has about 425 residues and the data resolution is 
> 1.5A.
>
> Thanks and regards
>
> S. Thiyagarajan
> Department of Cell and Organism Biology
> Lund University
> Sölvegatan 35
> Lund, Sweden
>
>