I can confirm this: I see the following running times for the exact same
job under linux with no other work being done on the machine:

ccp4.6.1.1

 Refmac_5.5.0072:  End of Refmac_5.5.0072
Times: User:     176.1s System:   78.2s Elapsed:     4:15 


ccp4.6.0.2
 Refmac_5.4.0062:  End of Refmac_5.4.0062
Times: User:      71.0s System:    5.5s Elapsed:     1:18 
 

ccp4-6.1.1 installed 2 days ago from the automatic download page.

i have not startet tracing the problem yet, a quick check on the ccp4
page did not show any known bugs. did i miss something ? it sure does
make a big difference for the user.

ingo

Philip Leonard wrote:
>
> Have any other Windows users noticed that Refmac5 runs much slower on
> the same job when you upgrade from CCP4 6.0.2 to 6.1.1?
>
>  
>
> Best regards,
>
>  
>
> Phil Leonard.
>
>  
>
>
> ------------------------------------------------------------------------
>
> "DISCLAIMER: This e-mail and any attachments are confidential. They
> may contain privileged information and are intended for the named
> addressee(s) only. If you are not the named addressee do not
> disseminate, distribute, copy or retain this e-mail, or any part of
> it, in any manner. Please notify the sender immediately if you have
> received this e-mail by mistake and delete it from your system. The
> sender does not accept any liability for any errors or omissions in
> the contents of this message, which arise as a result of e-mail
> transmission. Unless expressly stated, opinions in this e-mail are
> those of the individual sender, and not of Galapagos NV or any of its
> subsidiaries including BioFocus DPI. Galapagos NV and its subsidiaries
> including BioFocus DPI reserve the right to monitor all e-mail
> communications through its network. Although this e-mail has been
> scanned for all known viruses, the sender does not guarantee that this
> message is virus-free and disclaims any liability for viruses that may
> be transmitted with this message."

-- 
CRELUX GmbH
 
Dr. Ingo Korndoerfer
Head of Crystallography

Am Klopferspitz 19a
82152 München
Germany

Phone: +49 89 700760210
Fax: +49 89 700760222 
[log in to unmask]
www.crelux.com

Amtsgericht München HRB 165552 - Managing Directors: Dr. Michael Schäffer, Dr. Ismail Moarefi

This e-mail contais confidential and/or privileged information. If you are not the intended recipient (or have received this e-mail in error) please notify the sender immediately and destroy this e-mail. Any unauthorized copying, disclosure or distribution of the material in this e-mail is strictly forbidden.
Diese E-Mail enthält vertrauliche und/oder rechtlich geschützte Informationen. Wenn Sie nicht der richtige Adressat sind oder diese E-Mail irrtümlich erhalten haben, informieren Sie bitte sofort den Absender und vernichten Sie diese Mail. Das unerlaubte Kopieren sowie die unbefugte Weitergabe dieser Mail ist nicht gestattet.