Print

Print


Hi Jason,

- run your model through TLSMD server to identify TLS domains (it will 
produce PHENIX friendly TLS groups selections);
http://skuld.bmsc.washington.edu/~tlsmd/

- use these selections for TLS refinement in PHENIX:
http://www.phenix-online.org/documentation/refinement.htm
for example, the command is:

phenix.refine model.pdb data.hkl 
strategy=individual_sites+individual_adp+tls  tls_selections.txt

Pavel.


On 10/17/2008 3:10 AM, [log in to unmask] wrote:
> Hi All,
>  
> I just refined a structure at 2.95A and getting a good R-work and 
> R-free(0.236 and 0.274). When I checked the PDB, I found many  
> residues have high temperature factor over 100. How can I use Phenix 
> or CNS fix those high temperature factor for further refinment?
>  
> Thank you
> Jason
>  
> ------------------------------------------------------------------------
>
> _______________________________________________
> phenixbb mailing list
> [log in to unmask]
> http://www.phenix-online.org/mailman/listinfo/phenixbb
>