Print

Print


Hi - yes, sorry target->MNI-space registration in  tbss_3 will work  
better if you change reference to the MNI152 in it to the FMRIB58_FA_1mm
This is changed in the new upcoming version for just this reason.
Cheers.


On 23 Apr 2008, at 22:04, Conrad Rockel wrote:

> regarding post 017289
>
> After a bit more tinkering, I found that nothing seems to want to  
> register
> (with flirt)to the MNI152_T1 scan!  However, individual  
> registrations were
> successful with its skull-stripped counterpart, as well as with the  
> FA58.
> The smaller data set I ran as a test with the '-T' option has not  
> finished
> yet to see if successful.
>
> Since I am dealing with a pediatric population, I wanted to use one  
> of our
> own subjects.  Could something be wrong with my MNI152?  Should I  
> edit the
> tbss_3 script to hardwire a different image (eg the FA58, which  
> could be
> the same as using '-T', or the skull-stripped MNI152) for the  
> purposes of
> moving the target into standard space?
>
> Cheers,
>
> Conrad
>


---------------------------------------------------------------------------
Stephen M. Smith, Professor of Biomedical Engineering
Associate Director,  Oxford University FMRIB Centre

FMRIB, JR Hospital, Headington, Oxford  OX3 9DU, UK
+44 (0) 1865 222726  (fax 222717)
[log in to unmask]    http://www.fmrib.ox.ac.uk/~steve
---------------------------------------------------------------------------