Sent on behalf of Kazuhiro Yamada ([log in to unmask] )
I am trying to use CNS ver. 1.2 for structural refinement of
our crystal containing three 1:1 hetero complexes with pseudo-3fold symmetry in
the A.U.([A1B1], [A2B2] and [A3B3]).
Following initial model building and refinement the rotation
matrices & translation vectors of the A molecules (from 1 to 2, or 1 to 3)
are slightly different from the corresponding transformations for the B
molecules due to a relatively loose interaction between the A and B components.
Thus at the simulated annealing step I want to define two versions of
ncs_matrix_2 (A1 to A2 versus B1 to B2)
and two of ncs_matix_3 (A1 to A3 versus B1 to
B3). However, there is no template describing such a case on the
CNS ver1.2 homepage.
Does someone who is well acquainted with NCS know how to address
such a case? What should I do practically…, average the two sets of
ncs_matrix_2 & _3? Or write a special subroutine / script to handle it?
Thanks for any tips.
Kazuhiro
_________________________________________________________________________________________________________________________________________________
Dr. D.F. Sargent
ETH-Hönggerberg
CH-8093 Zürich
Switzerland
tel (+41) (0)44 633 2487