Hello,
I am trying to convert Dicom files acquired on the Philips Achieva scanner using the DICOM import option in SPM. However, I get the following errors when using this function:
***********************************************************
Running "DICOM Import"
Changing directory to:
C:\fmri_data\Finger_Tapping\NIFTI_format\Ana_401\
***************************************************
*
The AcquisitionNumber counter does not appear *
* to be changing
from one volume to another. *
* Another
possible explanation is that the same *
* DICOM slices are used
multiple times.
*
* The conversion is having to guess how slices *
*
should be arranged into
volumes.
*
* TESTFINGER_TAPPING / 401 /
4
***************************************************
??? Error using
==> feval
Undefined command/function 'offset'.
Error in ==> file_array.subsasgn>asgn at 144
obj
= feval(fun,obj,dat);
Error in ==> file_array.subsasgn at
22
case
'offset', obj = asgn(obj,@offset,
subs(2:end),dat); %offset(obj,dat);
Error in ==> nifti.subsasgn>assigndat at
361
val.offset =
max(sval.offset,0);
Error in ==> nifti.subsasgn>fun at
76
obj = assigndat(obj,val);
Error in ==> nifti.subsasgn at
20
obji =
fun(obji,subs,val);
Error in ==> spm_dicom_convert>write_volume at 564
N.dat =
file_array(fname,dim,dt,0,pinfo(1),pinfo(2));
Error in ==> spm_dicom_convert>convert_standard at
207
write_volume(hdr{i},root_dir,format);
Error in ==> spm_dicom_convert at 44
convert_standard(standard,root_dir,format);
Error in ==> spm_config_dicom>convert_dicom at
130
spm_dicom_convert(hdr,'all',root_dir,job.convopts.format);
Error in ==> spm_jobman>run_struct1 at
1540
feval(prog,val);
Error in ==> spm_jobman>run_struct1 at
1548
run_struct1(c.val{i});
Error in ==> spm_jobman>run_struct1 at
1548
run_struct1(c.val{i});
Error in ==> spm_jobman>run_job at 469
run_struct1(c);
Error in ==> spm_jobman>serial at 2128
run_job(jobs);
Error in ==> spm_jobman at
76
serial(varargin{2:nargin});
??? Error while evaluating uicontrol Callback.
*********************************************************************
Is this because the dicom files are not suitable for conversion into NIFTI format?