yes, at last I was able to reconfigure
correctly the lcg-CE. I reset the correct BDII_CE value and had to reenable
the variables VO_$VO_QUEUE values which I had understood that were not
needed anymore.
Re: [LCG-ROLLOUT] - Production - lcg-CE
- Update 21
On Thu, 19 Apr 2007, Vega Forneris wrote:
> Hi *,
>
> I've just reconfigred my CE (lcg like), it works if targeted by
> globus-job-run (both fork and lcgpbs scheduler), but it disappeard
from
> top BDII.
>
>
>
> Looking in the specific release note, I found:
>
>
> In the site-info.def file is necessary to define the BDII_CE_URL parameter
> as follows:
>
> BDII_CE_URL="ldap://$CE_HOST:2170/mds-vo-name=resource,o=grid"
It says to do that when the site BDII is _not_ on the CE.
Furthermore, AFAIK it only applies to the gLite CE;
the LCG-CE still runs an MDS on port 2135 instead.
> so I changed the value accordly (well...just cut and paste!) and launched
> the reconfiguration of the bdii side:
>
> /opt/glite/yaim/bin/yaim -r -s /home/shared/conf/esrin-site-info.def
-n
> lcg-CE_torque -n BDII_site -f config_bdii
>
> but nothing changed...should I wait (maybe it needs to repopulate
the top
> BDII) or should I be worried?
The repopulation is done about every 2 minutes...
Apparently you fixed it somehow: your CE does appear now.