> However when I try and use this shift list to generate a synthetic peak list
> in my new project it works but it only produces 215 peaks. The same
> shiftlist in my source project produces 422 peaks. When I look at my
> shiftlist it all seems ok and the shifts that have "zero shift list peaks"
> are correct (I can pick these peaks manually).

I suspect that this is something to so with the resonance-resonance
covalent links. Try unsetting and resetting the experiment type for the
spectrum for which you are trying to generate peaks.


> ps. Another thing I noticed is that if I read in a spectrum into Analysis
> then it wont appear in the synthetic shift list pulldown until I quit and
> restart Analysis. I am sure it used to appear after just closing and
> reopening the Current Peak List pop-up.

We haven't knowingly changed anything. Fixed nonetheless.

T.

-------------------------------------------------------------------------------