> However when I try and use this shift list to generate a synthetic peak list > in my new project it works but it only produces 215 peaks. The same > shiftlist in my source project produces 422 peaks. When I look at my > shiftlist it all seems ok and the shifts that have "zero shift list peaks" > are correct (I can pick these peaks manually). I suspect that this is something to so with the resonance-resonance covalent links. Try unsetting and resetting the experiment type for the spectrum for which you are trying to generate peaks. > ps. Another thing I noticed is that if I read in a spectrum into Analysis > then it wont appear in the synthetic shift list pulldown until I quit and > restart Analysis. I am sure it used to appear after just closing and > reopening the Current Peak List pop-up. We haven't knowingly changed anything. Fixed nonetheless. T. ------------------------------------------------------------------------------- Dr Tim Stevens Email: [log in to unmask] Department of Biochemistry [log in to unmask] University of Cambridge Phone: +44 1223 766018 (office) 80 Tennis Court Road +44 7816 338275 (mobile) Old Addenbrooke's Site +44 1223 364613 (home) Cambridge CB2 1GA WWWeb: http://www.bio.cam.ac.uk/~tjs23 United Kingdom http://www.pantonia.co.uk ------------------------------------------------------------------------------- ------ +NH3CH(CH(CH3)OH)C(O)NHCH(CH(CH3)CH2CH3)C(O)NHCH(CH2CH2SCH3)CO2- ------- -------------------------------------------------------------------------------