Hi

I’ve decided to do the VBM on FA maps with the following pipeline but
still I have some points to decide:

1.      Eddy and motion correction. I don’t have fieldmaps to make
geometric distortion due to susceptibilities changes. I don’t know a
method to correct signal loses…
2.      Normalization of native images to a standard space using linear
affine 12 parameters. This can be done without nonlinear warping to
reflect variability in a common standard space, my goal in this step is
to make a diffusion template. The possibilities can be:

a.      Native b0 --> EPI template
b.      Native whole head EPI (obtained using the common sequence to
functional BOLD imaging) (previously registered to b0 native)  --> EPI
template

 “I think option a. quarantines better registration of diffusion data to
standard space. However, I propose b. because I’m afraid b0 intensity is
too low and maybe this can affect the registration process in someway.
Furthermore, although one uses a single shot EPI sequence like
functional BOLD imaging (which is the of the same modality of EPI
template) to obtain b0 image, some differences can be found between b0
and BOLD-EPI that makes me suspect they are not exactly of the same
modality (I think, anyway, this can be circumvented using mutual
information). 

Finally, I can consider, as the reference image or template, the T2
template if this entails better results 

3.      I’d like to somehow mask images to remove edge effects that
arise when a wrong brain extraction is done. This is very important
because hyperintensities appear in the edges of the FA maps due to the
very noisy nature of diffusion images in voxels outside the brain. In my
opinion this is unacceptable for the construction of a template. 

a.      I can mask the b0 (again the low intensity problem arises). This
time I can use BET-FSL or some masking routine in SPM I don’t know.
b.      I’ve tried probability segmentations to define automatically an
inside brain region (this leave most of the time a fine line of
hyperintensity)

4.      Once all natives images are in standard space to obtain mean
image. This will used as the reference image to re-normalize the
diffusion b0 images. In this step, I don’t know if nonlinear warping
should be used.

 

Is there any other step missing here (e.g. intensity correction)?

Please, I’ll appreciate if a hard criticism if done.

Thank you for your time…

 