Print

Print


Hi Martin!

Do you really need the DICOM data sets? Philips does provide an export tool that
allow to export 4D data sets which can be simply converted into the ANALYZE
format. If you try this way I could provide you with a simple matalb script


best wishes and good luck!

Lukas

.
However, if you have to use the DICOMS it should be not too difficult to write a
simple shell script that does the job.

Datum:          Mon, 10 Jan 2005 11:07:19 +0100
Antwort an:             FSL - FMRIB's Software Library <[log in to unmask]>
Von:                    Martin Kavec <[log in to unmask]>
Betreff:                [FSL] DICOM 4D series from Philips
An:                     [log in to unmask]

> Hi,
>
> I am trying to analyze a motor activation study (which I have never done
> before) on a dataset acquired on a Philips Intera scenner. The data are
> ordered as follows:
> slice-1(t1).dcm
> ....
> slice-1(tn).dcm
> slice-2(t1).dcm
> ....
> slice-2(tn).dcm
> ....
> slice-N(t1).dcm
> ....
> slice-N(tn).dcm
>
>
> I couldn't find a way to reorder/convert it from DICOM  to a form
>
> slice-1(t1).dcm
> ....
> slice-N(t1).dcm
> slice-1(t2).dcm
> ....
> slice-N(t2).dcm
> ....
> slice-1(tn).dcm
> ....
> slice-N(tn).dcm
>
> using MRIcro nor with XmedCon. Perhaps, I missed information on how to do
> that, but I am turning to the list because I don't want to reinvent a wheel.
>
> So, please what do you use to order/convert Philips dicom data so they are
> suitable for FEAT.
>
> Thanks.
>
> Martin