Hi - all the stats values within the mask are weighted (before being used
to calculate min, mean, max etc) when you turn on the weighting button - 
hence all the output stats values can potentially change, including the 
max.

Cheers.



On Tue, 13 Sep 2005, Armin Biller wrote:

> Hi there,
> 
> using featquery, I found the max-value (of, for example, PE/COPE values
> converted to %) to be changed when weighting is allowed (i.e. when the
> mask is not binarised). I see why median etc. should change, but I miss
> the point why weighting should affect max and min. Does it make sense to
> report max % changes estimated from weighted mask at all? Any
> considerations would be very helpful to me.
> 
> Thanks a lot in advance!
> 
> Ciao,
> Armin
> 

-- 
 Stephen M. Smith  DPhil
 Associate Director, FMRIB and Analysis Research Coordinator

 Oxford University Centre for Functional MRI of the Brain
 John Radcliffe Hospital, Headington, Oxford OX3 9DU, UK
 +44 (0) 1865 222726  (fax 222717)

 [log in to unmask]  http://www.fmrib.ox.ac.uk/~steve