Print

Print


Sorry we haven't responded earlier. I'll first need to know which OS
your running under. Also is your current FSL installation the only one
or do you have an older version hanging around?

On 22 Oct 2004, at 13:32, Jay Ives wrote:

> Tim,
>
> Is there any update on this GUI problem in FDT yet?
>
> Thanks
>
> J
>
>> Also, I can run the tools from a command line , but I get an error if
>> I
>> try to use the GUI. Here is the message.....
>>
>> bad cursor spec " watch red white "
>> bad cursor spec " watch red white "
>>     (processing "-cursor" option)
>>     invoked from within
>> "$w configure -cursor { watch red white } "
>>     (procedure "fdt_monitor" line 5)
>>     invoked from within
>> "fdt_monitor $w "${FSLDIR}/bin/eddy_correct $eddy(input) $eddy(output)
>> $eddy(refnum)""
>>     ("eddy_current" arm line 18)
>>     invoked from within
>> "switch -- $tool {
>>  eddy_current {
>>      global eddy
>>
>>      set errorStr ""
>>      if { $eddy(input) == "" } { set errorStr "You need to specify
>> the input ..."
>>     (procedure "fdt:apply" line 7)
>>     invoked from within
>> "fdt:apply .fdt keep"
>>     invoked from within
>> ".fdt.apply invoke"
>>     ("uplevel" body line 1)
>>     invoked from within
>> "uplevel #0 [list $w invoke]"
>>     (procedure "tkButtonUp" line 9)
>>     invoked from within
>> "tkButtonUp .fdt.apply
>> "
>>     (command bound to event)
>>
--
Regards,

Dave


Dave Flitney, Computer Manager
Oxford Centre for Functional MRI of the Brain
E:[log in to unmask] W:+44-1865-222713 F:+44-1865-222717
URL: http://www.fmrib.ox.ac.uk/~flitney