Dear All,
No-one answered my query about REd hat 6.1 and Matlab 5.3 and so we tried
using Matlab 5.2 This seemed to work using the precompiled binaries for
image display and realignment. However I got the following error on trying
to do slice timing:
SPM99b: spm_slice_timing (v2.2) 12:00:59 - 29/11/1999
========================================================================
??? In an assignment A(matrix,matrix) = B, the number of rows in B and
the number of elements in the A row index matrix must be the same.
Error
in ==> /home/ejw1001/spm99b/spm99b/spm_slice_timing.m On line 186 ==>
stack(nimgo+1:size(stack,1),g) =
linspace(stack(nimgo,g),stack(1,g),nimg-nimgo)';
??? Error while
evaluating uicontrol Callback.
The scans also did not normalised (and have done previously).
Is this some weird byte order effect?
Some help would be very welcome!
Emma Williams
,---------------------------------------------------------------------.
| Emma Williams |
| MRI Physicist, Wolfson Brain Imaging Centre |
+----------------------------------------------------------------------+
| Wolfson Brain Imaging Centre |Email: [log in to unmask] |
| |Phone email: [log in to unmask] |
| University of Cambridge, |Tel (MR suite): +44 1223 331821 |
| Box 65 Addenbrooke's Hospital|Tel (Analysis): +44 1223 331823 |
| Hills Road |FAX: +44 1223 331826 |
| Cambridge, UK, CB2 2QQ |http://www.wbic.cam.ac.uk/~ejw1001 |
`----------------------------------------------------------------------'
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|